For your lab, a monitoring programme is set up once and then repeats: the tests and units live in OnLAB, the working columns and formulas in an OnWSH template. Each run records the preparation values, imports the instrument readings into the matching columns and calculates the results, and range flags and QC are reviewed before anything is published.
Monitoring points as routine jobs, campaigns as batches
Recurring sampling and finite campaigns each get the job type that suits them. A routine job is created once with its tests and units and keeps collecting samples over time; by default each sample is identified with the routine name, date and time, so successive monitoring events stay in order. A finite campaign becomes a batch job with its own sample list and tests. Both feed the same worksheets.
- Recurring points One routine per monitoring programme, with dated sample identities for each event.
- Results in one job The routine accumulates every event, so the history of a programme is reviewed in one place.
- Sample identity Each worksheet row keeps its Sample ID and job link, and the instrument’s sample identifier is matched to the row on import.
Import readings with their sample and unit
Readings are not retyped. The instrument export file is imported into the worksheet, and each value lands in the column of its element and unit: for example, Cu in mg/L by AA goes to the CuAA column. ICP files are imported the same way, element by element, and the import is recorded in the worksheet’s instrument log before the result columns are calculated.
Limits, detection limits and QA/QC in the run
- Range flags Each test carries a minimum, maximum and standard deviation. A result above the maximum appears red and one below the minimum appears yellow, so exceedances stand out on the job.
- QC during locking When results are locked, OnWSH checks every standard, blank and duplicate against its QC record. An out-of-range result opens the Control Chart window; the analyst cancels and repeats, or accepts it with a written note.
- Instrument dates The instrument’s calibration and service expiry dates are recorded with the run, and OnWSH shows them before an on-line reading when they have expired.
Publish, preview and export
Clients and receiving systems only see what you have released. The approved worksheet sends its results to the OnLAB job, where they are published before the certificate is printed or the job is exported. Job export writes CSV, XLSX or XLS, and any value not yet published stays masked. In LabData, clients view their published results according to their account access.
Detection limits and reporting notation
Each result column carries its detection limit. With a limit of 0.10, a calculated Cu of 0.05 is shown as 0.10 and the calculated value is kept. For receiving systems that need numbers only, job export can write values below the detection limit as negatives: <0.01 becomes -0.01.
Review a correction and its records
A correction to a published result never happens silently. An authorised user unpublishes the value with a password, edits it (for example, from 10.00 to 12.50) and publishes it again after review, while the other results stay published. The job’s Audit Viewer lists the recorded events by date, user, sample and test, with previous and new values, and exports them to Excel.
Related: Sample tracking and chain of custody · ICP integration · QA/QC for mining labs
Frequently asked questions
Can OnLIMS run an environmental monitoring laboratory?
Yes. Recurring points run as routine jobs and finite campaigns as batch jobs. Tests and units are defined once, readings are imported into the worksheet, and QC is checked before approval and publication.
How are range limits shown?
Each test in OnLAB has a minimum, maximum and standard deviation. A result above the maximum appears red and one below the minimum appears yellow, so exceedances are visible as soon as results are entered.
Which instruments can feed environmental results directly?
OnLIMS connects 150+ instruments, including AAS, ICP-OES/MS and balances. Models in the catalogue include the Agilent 5110 ICP-OES, the PerkinElmer NexION 2000x ICP-MS and the PerkinElmer Lambda25 UV-Vis.
Can clients consult published results?
Yes. In LabData, clients follow their samples and view published results according to their account access; values not yet released stay masked.