Geochemical data ages into resource models, and resource models get audited. A concentration reported today may be questioned years later during an NI 43-101 or ISO/IEC 17025 review — which sample, which instrument run, which reference material, whose approval. A geochemical laboratory therefore needs more than throughput: it needs every number to remain explainable long after the batch has left the building. That is the problem OnLIMS is built around.
Multi-element work without transcription
For your laboratory this means a multi-element package goes from the instrument file to the certificate without anyone retyping a value.
- Analytical packages Job templates hold the requested tests and units of each package; worksheet templates hold each method’s columns, formulas, units, formats and detection limits. Templates are kept as named revisions — for example “Routine metals rev 02” — so a method change is visible.
- Instrument capture ICP-OES/MS, XRF, AAS and carbon/sulfur readings are imported from the instrument’s own file, with a preview of sample sequence, elements and units before they land. OnLIMS connects to 150+ instruments from about 40 brands, including Agilent 5110 and Thermo Scientific iCAP ICP-OES, PerkinElmer NexION ICP-MS and Bruker S8 Tiger XRF.
- Detection limits applied A result below the detection limit displays the limit while the calculated value is kept: a Cu result of 0.05 with a limit of 0.10 displays 0.10. Below-limit notation is never improvised in a spreadsheet.
- Export to geology Published results leave OnLAB as CSV, XLSX or XLS files for the geology database and modelling packages. Values not yet published are never exported as numbers.
Campaigns as batch jobs
An exploration campaign arrives as a large, finite set of drill-core samples that must move through preparation and analysis as a unit. An OnLAB batch job gives each sample a unique ID at registration, checked against the submittal, and an earlier job or template can be copied when the requested tests repeat. Each sample carries its preparation note, and preparation checks are calculated on the worksheet — a pulp-size check with 100 g total and 5 g retained gives 95 % passing. Worksheet templates carry the certified reference materials, blanks and duplicates with the samples, so QA/QC coverage is designed into the run rather than added afterwards, and repeat readings are added as replicate rows of the same sample.
QA/QC that will survive an audit
For your laboratory this means an assessor can follow any QC decision back to its reading. When results are locked, OnWSH checks standards, blanks and duplicates against the limits of their QC record; an out-of-range result opens the Control Chart window, where the analyst cancels to investigate or an authorized analyst accepts it with a note, and the accepted value stays red, bold and underlined. OnQC plots reference materials on Shewhart, X-Control and cumulative-sum charts with lines at one, two and three standard deviations, and duplicate pairs on replicate, percentage-of-replication, range-control and range-ratio charts — the classic geochemical evidence set, each point traceable to its source worksheet. Behind it, result changes are logged with previous and new value, user and time, and Job Audit lists every recorded event of the job, with export to Excel.
Frequently asked questions
How does OnLIMS handle multi-element geochemical packages?
Job templates hold the requested tests and units of each package, and worksheet templates hold each method's columns, formulas, units and detection limits. ICP-OES/MS, XRF and AAS readings are imported from the instrument file into their worksheet columns, with no transcription.
What happens to a result below the detection limit?
The worksheet displays the detection limit and keeps the calculated value behind it. For example, a Cu result of 0.05 with a limit of 0.10 displays 0.10, so nobody improvises below-limit notation in a spreadsheet.
What QA/QC evidence does a geochemical laboratory get for audits?
Standards, blanks and duplicates are checked against their QC record as results are locked, with every accepted exception noted and flagged. OnQC charts reference materials on Shewhart, X-Control and cumulative-sum charts and duplicates on precision charts, each traceable to its source worksheet, and Job Audit lists the recorded events of every job.
Related: Mining laboratory LIMS · Gold mine laboratory LIMS · Instrument integration · ISO 17025 LIMS
Related reading
- Article Securing the Digital Audit Trail: Data Integrity and Instrument Validation in Mining Laboratory LIMS
- Article Mine Production Reconciliation: Where Grade Control, Plant Performance and Laboratory Data Must Agree
- Article Before the Assay: Controlling Sample Preparation Risk in Mining Laboratory LIMS
- Solution ICP LIMS integration
- Solution XRF LIMS integration