What this means for your laboratory: analysts stop retyping results, and every reported value can be traced back to the instrument that produced it. The OnLIMS connection catalogue lists 150+ instruments from about 40 brands, including Agilent, PerkinElmer, LECO, Metrohm, Thermo Scientific, Malvern PANalytical, Eltra, Varian, Teledyne Leeman Labs, Spectro, Bruker, Rigaku, Chrysos (PhotonAssay), Parr, IKA and CKIC, across AAS, ICP-OES/MS, XRF, carbon/sulfur, calorimeters, titrators and balances.
Two ways in: file import and live balance reading
- Instrument file import A reader supplied by OnLIMS translates the instrument's export. The import preview shows each element, its unit and the worksheet column it will fill before anything is written. Readers cover ICP-OES/ICP-MS, AAS, PANalytical Axios XRF and LECO CS744 exports, among others.
- Live RS232 reading Balances send each weight straight into the selected sample's cell; the cursor moves to the next sample and the results recalculate.
- Technique suffixes An AAS file reports Cu in mg/L; the suffix AA links it to the CuAA column, so the same element measured by AAS and by ICP lands in different columns of the worksheet.
Instruments in the connection catalogue
- ICP Examples include Agilent 5100, 5110, 5800, 5900 and 7900; Spectro Arcos and Ciros; Perkin Elmer Avio 550 max; Thermo Scientific iCAP 6000; Varian 725-ES; Teledyne Leeman Labs Prodigy.
- Atomic absorption Agilent 240AA, 240FS, 55AA, AA240, AA240-280; GBC SavantAA; Varian Spectra AA; Perkin Elmer 400, 500, Analyst 400, PinAAcle 900, PinAAcle 900F.
- XRF Examples include PANalytical Axios and Axios PL, Bruker S8 Tiger, Rigaku Supermini 200 and ZSX Primus IV, and Spectro Xepos v5.
- Titration Metrohm OMNIS, 815 Titrator, 815 Titrator2, 815 Titrator3, 815-905 Titrator3, 848 Titrino Plus; Mettler Toledo GS20Sx; SI Analytics 7000; Aquamax KF Coulometric.
- Carbon, sulfur and elemental analysis LECO 230CS, CS 844, CS744, CN 828v2 and TruSpec; Eltra CS-200x, CS800x, CSi, 580, CHS and Elementrac; Elementar Vario MACRO cube.
- Gold, calorimetry and more Chrysos PhotonAssay; calorimeters from CKIC, IKA, LECO and Parr; Metrohm and Dionex ion chromatographs; CETAC, Mitsubishi and Teledyne Leeman Labs mercury analyzers; Malvern Mastersizer 3000E particle sizing.
From a reading to a published result
Every step leaves a record an auditor can follow, from the instrument file to the published value.
- 1. Import Readings are matched to sample rows and columns. Each cell keeps the instrument and the reading as imported, and the import log records the source file, the reading count and the analyst.
- 2. Calculate The template's formulas turn readings, weights, volumes and dilutions into reportable results. A result below the detection limit shows the limit while the calculated value is kept.
- 3. Review QC Locking checks standards, blanks and duplicates against their QC limits. An out-of-range value opens the Control Chart window for a documented decision.
- 4. Approve and export The approved worksheet is exported to OnLAB with a count of the results sent; publishing at export requires its own permission. Any later manual change is logged with date, time, user, previous and new value.
Frequently asked questions
How many instruments can OnLIMS connect?
The OnLIMS connection catalogue lists 150+ instruments from about 40 brands across AAS, ICP-OES/MS, XRF, carbon/sulfur, calorimeters, titrators and balances.
Can titrators send results to the LIMS?
Yes. The connection catalogue includes Metrohm OMNIS, 815 Titrator and 848 Titrino Plus, Mettler Toledo GS20Sx, SI Analytics 7000 and Aquamax KF Coulometric. The receiving worksheet columns are set up with your titration method.
Where are calibration and service dates checked?
From any instrument reading in the worksheet, the instrument's properties show its calibration and service dates with their expiration. When an on-line balance's dates have expired, OnWSH shows them before reading starts.
Which export format should the instrument use?
The layout its reader is built for. OnLIMS has readers for the main ICP families (Agilent, MassHunter, Thermo, NexION, Varian, Spectro, Prodigy) and for specific XRF and LECO exports, and sets up the one that matches your instrument software.
Related: QA/QC for mining labs · Sample tracking · Fire assay LIMS · How to select a mining LIMS · ICP integration · XRF integration · Balance integration · LECO integration
Related reading
- Article Instrument Integration and Data Capture in Mining Laboratory LIMS: Eliminating Manual Transcription
- Article From Endpoint to Audit Trail: Digitizing Titration Workflows in Mining and Chemical Laboratories
- Article Mettler Toledo Analytical Balance Integration for Mining LIMS and QA/QC Traceability
- Solution ICP LIMS integration
- Solution Balance LIMS integration